Pure Steam Generator
Capacity 50 to 1000 kg./hr.
Application
- Used for Sterilization of vessel / Pipeline /Reactors & Inner chamber of autoclave.
Features :
- Fully Automatic Control Panel with Touch Screen, online Conductivity for Feed water & outlet of Pure Steam
- All tubes are seamless pipes / Electro polished
- Total Organic Carbon (TOC) – 100 PPB.
- All gaskets are Teflon.
Technical Specifications:
- Purified water with max. conductivity of 0.5 micro ohms/cm. should be used.
- Pressure should be 1 kg/cm.sq. higher than the in feed steam pressure.
- Temperature Ambient 30oC
- Outlet of clean steam pressure 3 kg./cm.²
Operation
- To produce pyrogen free sterile steam confirming to IP/ BP / USP Specification
- Endotoxing less than 0.25 eu/ml
- Low maintenance cost.